Read an integer parameter from a configuration file
#include <photon/PxProto.h> int PxConfigReadInt( const char *section, const char *entry, int dflt, int *value ); int PxConfigReadIntCx( PxCfgContext_t *cx, const char *section, const char *entry, int dflt, int *value );
phexlib
These functions read an integer parameter from a configuration file.
The value can be signed. The characters after the sign determine the base:
Character(s): | Base: |
---|---|
0x or 0X | Hexadecimal |
0 | Octal |
Other digits | Decimal |
PxConfigReadInt() reads from the currently open configuration file opened by PxConfigOpen(), while PxConfigReadIntCx() reads from the configuration file indicated by cx.
Pt_TRUE if the required section/entry exists and the given value is valid, otherwise Pt_FALSE.
Photon
Safety: | |
---|---|
Interrupt handler | No |
Signal handler | No |
Thread | No |
PxConfigOpen*(), PxConfigReadBool*(), PxConfigReadChar*(), PxConfigReadDouble*(), PxConfigReadLLong*(), PxConfigReadLong*(), PxConfigReadShort*(), PxConfigReadString*(), PxConfigWriteBool*(), PxConfigWriteChar*(), PxConfigWriteDouble*(), PxConfigWriteInt*(), PxConfigWriteLLong*(), PxConfigWriteLong*(), PxConfigWriteShort*(), PxConfigWriteString*()